In-phase and out-of-phase sequences

Andrew Murphy and Dr Bruno Di Muzio et al.

In-phase (IP) and out-of-phase (OOP) sequences correspond to paired MRI gradient echo (GRE) sequences obtained with the same repetition time (TR) but with two different echo time (TE) values. 

Applications

The main application of the IP-OOP sequences is to identify pathological (microscopic) fat content of tissues in the abdomen by showing signal intensities drop on the OOP images compared to the IP images. Examples where IP-OOP sequences are useful include 1,2:

Imaging technology

Article information

rID: 42534
Tag: refs, refs
Synonyms or Alternate Spellings:
  • Opposed-phase imaging
  • Chemical shift cancellation artifact
  • Opposed-phase
  • In-phase and out-of-phase sequences
  • In-phase/out-of-phase
  • In-phase and out-of-phase
  • IP and OOP
  • IP/OOP
  • IP-OOP

ADVERTISEMENT: Supporters see fewers/no ads

Cases and figures

  • Case 1: lipid-rich left adrenal adenoma
    Drag here to reorder.
  • Case 2: lipid-poor hepatic adenoma
    Drag here to reorder.
  • Case 3: fatty liver
    Drag here to reorder.
  • Case 4: lipid-rich hepatic adenoma
    Drag here to reorder.
  • Case 5: focal fatty change
    Drag here to reorder.
  • Case 6: lobar distribution pattern of the focal fatty infiltration
    Drag here to reorder.
  • Case 7: lipid-rich right adrenal adenoma
    Drag here to reorder.
  • Case 8: hemochromatosis
    Drag here to reorder.
  • Case 9: lipid-rich left adrenal adenoma
    Drag here to reorder.
  • Case 10: primary hemochromatosis
    Drag here to reorder.
  • Updating… Please wait.

     Unable to process the form. Check for errors and try again.

     Thank you for updating your details.